Showing 1–9 of 23 results
-

Live AMR106B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 10A
£10.75 View ProductLive AMR106B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 10A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 10
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR110B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live AMR106B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 6A
£10.75 View ProductLive AMR106B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 6A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 6
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR106B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live AMR116B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 16A
£10.75 View ProductLive AMR116B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 16A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 16
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR116B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live AMR120B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 20A
£10.75 View ProductLive AMR120B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 20A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 20
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR120B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live AMR132B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 32A
£10.75 View ProductLive AMR132B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 32A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 32
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR132B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live AMR140B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 40A
£10.75 View ProductLive AMR140B-030 Double Pole Single Module Bidirectional RCBO 6kA Mini B Curve 40A
AMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40 A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off .
- Switching and isolation.
- Overload and short circuit protection.
- Type A detects and respond both AC and pulsating DC.
- Indirect and direct contacts protection.
- Protection against fire hazard caused by insulation faults.
- Bidirectional.
- Single Module
- Double Pole
- Product Type: AMR Range
- Current Rating: 40
- Number of Module: 1
- Tripping Curve: B
- Operating SC Capacity: 6kA
- Device Type: Type A
- Residual Current (mA): 30
- Product Code: AMR140B-030
- Complies with BS EN61009-1
View Datasheet
£10.75 -

Live Electrical 10A Single Pole Type A Mini RCBO
£10.99 View ProductLive Electrical 10A Single Pole Type A Mini RCBO
Live Electrical 10A Single Pole Type A Mini RCBO
The Live Electrical B Type 10A 6kA 30mA Single Pole Type A Compact RCBO has been designed for use in Live Electrical Main Switch domestic consumer units. This Compact RCBO protects against both earth leakage and fault, preventing injury to humans and saving devices from current overload.
- Product Type:RSA Range
- Current Rating:10
- Number of Module:1
- Tripping Curve:B
- Operating SC Capacity:6kA
- Device Type:Type A
- Residual Current (mA):30
- Product Code:RSA110B-030
£10.99 -

Live Electrical 16A Single Pole Type A Mini RCBO
£10.99 View ProductLive Electrical 16A Single Pole Type A Mini RCBO
Live Electrical 16A Single Pole Type A Mini RCBO
The Live Electrical B Type 16A 6kA 30mA Single Pole Type A Compact RCBO has been designed for use in Live Electrical Main Switch domestic consumer units. This Compact RCBO protects against both earth leakage and fault, preventing injury to humans and saving devices from current overload.
- Product Type:RSA Range
- Current Rating:16
- Number of Module:1
- Tripping Curve:B
- Operating SC Capacity:6kA
- Device Type:Type A
- Residual Current (mA):30
- Product Code:RSA116B-030
£10.99 -

Live Electrical 2 Pole 80A 100mA RCD – RD280-100
£19.99 View ProductLive Electrical 2 Pole 80A 100mA RCD – RD280-100
Provides protection against earth fault/leakage current and function of isolation. High breaking current withstand capacity. Application to terminal and pin type busbar connection. Equipped with finger protection connection terminals. Flame resistant plastic parts endures abnormal heating and strong impact. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
- Pole: 2
- Rated current (A): 80
- Rated voltage: 240/415V AC
- Rated frequency: 50/60Hz
- Rated residual operating current (mA): 100
- Rated residual no operating current: 5
- Rated conditional breaking current (Inc): 6000A
- Rated conditional residual breaking current: 6000A
- Tripping duration Instantaneous tripping: 0.1s
- Residual tripping current range: 5
- Electro-mechanical endurance: 4000 cycles
- Connection capacity Rigid conductor up to 25mm
- Connection terminal screw terminal
- Fastening torque 2.0Nm
- Installation@ On symmetrical Din Rail 35mm
- Panel mounting
View Data Sheet
£19.99